1. Working voltage: DC8~18V2. Rated current: 1.5A3. Operating temperature: -40 ~ 125℃4. Working humidity: 95% Max5. Overall size: 26*15*5MM6. Protection type: under voltage, over voltage, over current, low temperature, over temperature, plugging, reverse connection, short circuit protection
1. Working voltage: DC8~18V2. Rated current: 5A3. Operating temperature: -40 ~ 125℃4. Working humidity: 95% Max5. Overall size: 47*52* 12.5mm6. Protection type: under voltage, over voltage, over current, low temperature, over temperature, plugging, reverse connection, short circuit protection7.PWM speed regulation, FG signal feedback8. Certified by CSIPER 259. Passed ISO11452-2 certification10. Passed ISO10605 certification11. Passed the ISO16750 environmental certification12. Passed the ISO7637 certification13. FOC sine wave control
1.Working Voltage: DC16~36V2.Rated Current: 10A 3.Working Temperature: -40~125℃ 4.Working Humidity: max 95% 5.Size: 90*84*21mm6.PWM speed regulation, PG signal feedback7.GB/T 18655 III certified8.ISO11452-2 certified9.ISO10605 certified10.ISO16750 certified11.ISO7637 certified12.FOC sine wave control13.Protection type: undervoltage/ overvoltage/ overcurrent/ low temperature/overtemperature/ blocking/ reverse connection/ short circuit protection.
1. Working voltage: DC16~36V2. Rated current: 20A3. Operating temperature: -40 ~ 125℃4. Working humidity: 95% Max5. Overall size: 90*84*21MM6. Protection type: under voltage, over voltage, over current, low temperature, over temperature, plugging, reverse connection, short circuit protection7.PWM speed regulation, FG signal feedback8.GB/T 18655 Level 3 certification9. Passed ISO11452-2 certification10. Passed ISO10605 certification11. Passed the ISO16750 environmental certification12. Passed the ISO7637 certification13. FOC sine wave control
1. Working voltage: DC16~36V2. Rated current: 10A3. Operating temperature: -40 ~ 85℃4. Working humidity: 95% Max5. Overall size: 87*84*15MM6. Protection type: under voltage, over voltage, over current, low temperature, over temperature, plugging, reverse connection, short circuit protection7. PWM speed regulation, FG signal feedback8. GB/T 18655 level 3 certification9. Passed ISO11452-2 certification10. Passed ISO10605 certification11. Passed the ISO16750 environmental certification12. Passed the ISO7637 certification13. FOC sine wave control
23页次3/3首页PREV123NEXT尾页
Contact Us
  • Skype:sales5@xc-bldc.com
  • E-mail:sales5@xc-bldc.com
  • (0086)180 2549 4183  0755-22183636-8007
  • 8F, Kechuang Building, Quanzhi Science and Technology Innovation Park, Shasong Road,

    Houting, Shajing Street, Baoan District, Shenzhen City, Guangdong Province, China


Copyright ©2005 - 2013 深圳市雄才科技有限公司
犀牛云提供企业云服务
ignore
X
1

QQ设置

3

SKYPE 设置

4

阿里旺旺设置

5

电话号码管理

    ignore
6

二维码管理

    ignore
返回顶部
展开