Products    Products     
产品列表
1. Working voltage: AC15~40V(50HZ/60HZ)2. Rated current: 8A3. Operating temperature: -40 ~ 85℃4. Working humidity: 95% Max5. Dimensions:   -Control panel 70 * 48.5 * 15 mm   -Power plate 100 * 65 * 39 mm6. Protection type: undervoltage, overvoltage, overcurrent, undertemperature, overtemperature,   -Blocking, reverse connection, short circuit protection7. Speed closed loop PID control8. Potentiometer stepless speed regulation, positive and negative control, foot control9. Adjustable speed from 1000RPM to 50000RMP,Every 1000 turns one gear
1. Working Voltage: DC7.2~16.8V 2. Rated Current: 30A (transient 120A) 3. Working Temperature: -40~85℃ 4. Working Humidity: max 95% 5. Size: 85*30*12mm 6. Protection: low/over voltage, over current, low/over temperature, block, inverse connection, short circuit 7. Current and speed closed loop PID control 8. Pass GB9706.1 certification
1. Working voltage: DC7.2~16.8V2. Rated current: 30A3. Operating temperature: -40 ~ 85℃4. Working humidity: 95% Max5. Overall size: 56*27*5MM6. Protection type: under voltage, over voltage, over current, over temperature, blocking, short circuit protection7. Double closed-loop PID control, current loop and speed loop8. Passed GB9706.1 certification
1. Working Voltage: DC16~36V 2. Rated Current: 2A (transient 10A) 3. Working Temperature: -40~125℃ 4. Working Humidity: max 95% 5. Size: ø50*5mm 6. Protection: low/over voltage, over current, low/over temperature, block, inverse connection, short circuit 7. Pass CSIPER 25 radiation and conduction level 3 certification 8. Pass ISO11452-2 EMS level 4 and BCI 100MA certification 9. Pass ISO10605 contact discharge 8KV and air discharge 16KV certification 10. Pass ISO16750 environment certification
1. Working Voltage: DC16~36V 2. Rated Current: 2.5A (transient 10A) 3. Working Temperature: -40~125℃ 4. Working Humidity: max 95% 5. Size: ø32.5*5mm 6. Protection: low/over voltage, over current, low/over temperature, block, inverse connection, short circuit 7. PWM speed regulation, CW/CCW and start/stop control 8. Pass CSIPER 25 radiation and conduction level 3 certification 9. Pass ISO11452-2 EMS level 4 and BCI 100MA certification 10. Pass ISO10605 contact discharge 8KV and air discharge 16KV certification 11. Pass ISO16750 environment certification
1. Working voltage: DC8~25V2. Rated current: 0.5A3. Operating temperature: -45 ~ 65℃4. Working humidity: 85% Max5. Dimensions: ø44.8* 3.27mm6. Protection type: under voltage, over current, over temperature, blocking protection7. Hall controls
1. Working Voltage: DC7.2~16.8V 2. Rated Current: 30A (transient 120A) 3. Working Temperature: -40~85℃ 4. Working Humidity: max 95% 5. Size: 85*30*12mm 6. Protection: low/over voltage, over current, low/over temperature, block, inverse connection, short circuit 7. Current and speed closed loop PID control 8. Pass GB9706.1 certification
1. Working Voltage: DC16~36V 2. Rated Current: 2A (transient 10A) 3. Working Temperature: -40~125℃ 4. Working Humidity: max 95% 5. Size: ø42*5mm 6. Protection: low/over voltage, over current, low/over temperature, block, inverse connection, short circuit 7. Pass CSIPER 25 radiation and conduction level 3 certification 8. Pass ISO11452-2 EMS level 4 and BCI 100MA certification 9. Pass ISO10605 contact discharge 8KV and air discharge 16KV certification 10. Pass ISO16750 environment certification
1. Working voltage: DC8~18V2. Rated current: 1.5A3. Operating temperature: -40 ~ 125℃4. Working humidity: 95% Max5. Overall size: 26*15*5MM6. Protection type: under voltage, over voltage, over current, low temperature, over temperature, plugging, reverse connection, short circuit protection
60页次6/7首页PREV1234567NEXT尾页
Contact Us
  • Skype:sales5@xc-bldc.com
  • E-mail:sales5@xc-bldc.com
  • (0086)180 2549 4183  0755-22183636-8007
  • 8F, Kechuang Building, Quanzhi Science and Technology Innovation Park, Shasong Road,

    Houting, Shajing Street, Baoan District, Shenzhen City, Guangdong Province, China


Copyright ©2005 - 2013 深圳市雄才科技有限公司