1. Working Voltage: DC16~36V 2. Rated Current: 7.5A (transient 15A) 3. Working Temperature: -40~125℃ 4. Working Humidity: max 95% 5. Size: ø33*5mm 6. Protection: low/over voltage, over current, low/over temperature, block, inverse connection, short circuit 7. Pass CSIPER 25 radiation and conduction level 3 certification 8. Pass ISO11452-2 EMS level 4 and BCI 100MA certification 9. Pass ISO10605 contact discharge 8KV and air discharge 16KV certification 10. Pass ISO16750 environment certification
1. Working Voltage: DC8~18V 2. Rated Current: 5A (transient 15A) 3. Working Temperature: -40~125℃ 4. Working Humidity: max 95% 5. Size: ø25.6*8mm 6. Protection: low/over voltage, over current, low/over temperature, block, inverse connection, short circuit 7. Pass CSIPER 25 radiation and conduction level 3 certification 8. Pass ISO11452-2 EMS level 4 and BCI 100MA certification 9. Pass ISO10605 contact discharge 8KV and air discharge 16KV certification 10. Pass ISO16750 environment certification
1. Working Voltage: DC16~36V 2. Rated Current: 2A (transient 10A) 3. Working Temperature: -40~125℃ 4. Working Humidity: max 95% 5. Size: ø42*5mm 6. Protection: low/over voltage, over current, low/over temperature, block, inverse connection, short circuit 7. Pass CSIPER 25 radiation and conduction level 3 certification 8. Pass ISO11452-2 EMS level 4 and BCI 100MA certification 9. Pass ISO10605 contact discharge 8KV and air discharge 16KV certification 10. Pass ISO16750 environment certification
1. Working Voltage: DC9~17V 2. Rated Current: 4.3A (max 8A) 3. Working Temperature: -40~125℃ 4. Working Humidity: max 95% 5. Size: 97*97*5.5mm 6. Protection: low/over voltage, over current, low/over temperature, block, inverse connection, short circuit 7. Pass CSIPER 25 radiation and conduction level 3 certification 8. Pass ISO11452-2 EMS level 4 and BCI 100MA certification 9. Pass ISO10605 contact discharge 8KV and air discharge 16KV certification 10. Pass ISO16750 environment certification 11. Pass ISO7637 1,2a 2b,3a 3b,4,5a certification
1. Working Voltage: AC15~40V(50HZ/60HZ) 2. Rated Current: 5A (transient 10A) 3. Working Temperature: -40~85℃ 4. Working Humidity: max 95% 5. Size:controller PCBA 70*48.5*15mm, power supply PCBA 100*65*28.7mm 6. Protection: low/over voltage, over current, low/over temperature, block, inverse connection, short circuit 7. Speed closed loop PID control 8. VR stepless regulation, CW/CCW control, pedal control 9. Speed regulation from 1000RPM~50000RPM, and one step per 1000RPM
1. Working Voltage: AC15~40V(50HZ/60HZ) 2. Rated Current: 8A (transient 10A) 3. Working Temperature: -40~85℃ 4. Working Humidity: max 95% 5. Size:controller PCBA 110*60*15mm, power supply PCBA 100*55*28.7mm 6. Protection: low/over voltage, over current, low/over temperature, block, inverse connection, short circuit 7. Speed closed loop PID control 8. VR stepless regulation, CW/CCW control, pedal control 9. Speed regulation from 1000RPM~50000RPM, and one step per 1000RPM
1. Working Voltage: DC7.2~16.8V 2. Rated Current: 30A (transient 120A) 3. Working Temperature: -40~85℃ 4. Working Humidity: max 95% 5. Size: 85*30*12mm 6. Protection: low/over voltage, over current, low/over temperature, block, inverse connection, short circuit 7. Current and speed closed loop PID control 8. Pass GB9706.1 certification
1. Working Voltage: DC7.2~16.8V 3. Rated Current: 30A (transient 120A) 3. Working Temperature: -40~85℃ 4. Working Humidity: max 95% 5. Size: ø22.3*4.7mm 6. Protection: low/over voltage, over current, low/over temperature, block, inverse connection, short circuit 7. Current and speed closed loop PID control 8. Pass GB9706.1 certification
1. Working Voltage: DC7.2~16.8V 2. Rated Current: 30A (transient 120A) 3. Working Temperature: -40~85℃ 4. Working Humidity: max 95% 5. Size: 85*30*12mm 6. Protection: low/over voltage, over current, low/over temperature, block, inverse connection, short circuit 7. Current and speed closed loop PID control 8. Pass GB9706.1 certification